For automatic controllers which control dehumidifying dryers, first indicator show state and operation of heat pumps. Next to indicator, a text description of current heat pump state is shown.
Following text might appear:
Below this indicator there is an indicator for fan cooling / drying. If this output is set to work with drying function, the indicator is constantly lit. If the output has cooling function, this indicator is flashing.
For automatic controllers for conventional dryers with ON / OFF type of control, there is only one indicator here for drying and it is lit whenever the output is turned on.
ON/OFF drying is off |
ON/OFF drying is on |
|
|
For automatic controllers for conventional dryers with PI type of control, this block shows how much drying dampers are open in percent.
For automates MC-600 and MC-2000 drying control can be manage manually. This is possible since version 1.0.6.4.
When the mouse hover above Drying panel, the mouse pointer changes to
.
Right click on the Drying panel opens pop-up menu, which content depends on the type of drying (ON/OFF or PI).
ON/OFF drying | PI drying |
|
|
auto - output is managed by MC according regime | auto - output is managed by MC according regime |
off - output is in manual mode and turned off | off - output is in manual mode and turned off |
on - output is in manual mode and turned on | open - output is in manual flaps-opened mode |
close - output is in manual flaps-closed mode |
While output is in manual mode, the display panel changes to