This box is used to display set and measured temperature, the temperature of each probe individually, and warnings that may occur related to temperature.>
Edit box show setpoint for temperature.> If the controller is in automatic mode, changing the value of set temperature
is not allowed.>
If controller is in the semi-automatic mode, change the value for temperature setpoint by
clicking the arrows beside text box. LED display shows average temperature taken from active probes. Actual measured value from
individual temperature probes is shown below display. Probes in passive state are shown in gray while active
probes are are shown in black.>
In case incorrect measurement value is received from temperature probe, then label error will be displayed instead of measured value.
Control temperature is displayed in bottom right corner of this box in case controller supports it.
Following labels can be displayed above LED display:
Under temperature setpoint indicator, label hold can be shown if the measured temperature deviates from the set temperature a lot.>
Symbols > or < can appear between temperature probes in case there is big difference between them.
Right click mouse button on temperature probes display to set each individual probe in passive or active state.
Right click
on the box to display the temperature
opens the popup menu for selecting the average.
Option average takes into account all active and correct probes and the average of these accounts (for example: (25.2 + 48.8) / 2 = 37.0).
Option maximum selects the probe with the highest value (example: 48.8).
Option minimum selects the probe with the lowest value (example: 25,2).