CONTROL OF THE DRYING PROCESS |
 |
|
|
 |
Automatic control unit used
for drying process control in dehumidifying and combined wood dryers (kilns)
MC-904 |

|
|
- Used in dehumidifying and conventional dryers
- Automatic control, semi-automatic control and control from a distance
- ON/OFF type of control
- Drying of all types of wood regardless of the starting moisture content
- 12 invariable and 8 variable (user) drying regimes
- 2 inputs for air temperature measurement
- 2 inputs for EMC measurement
- 1 control input
- Wood moisture content measurement in 6 points
- 8 relay outputs
- Data recording every 3 hours (up to one month)
- Alarm
- Communication
|
 |
MC-904 Automatic Control Unit for Wood dryers
is a device that automatically controls drying process in dehumidifying and
combined kilns mounted by "NIGOS-elektronik". Device achieves
optimal drying conditions in the chamber through air temperature and humidity
control.
Automatic control unit can control drying process based on the data
retrieved from a measurement probes in automatic, semiautomatic and remote
(via PC computer) control mode. Air temperature and EMC are measured in 2
points, while wood moisture content is measured in 6 points.
In automatic control mode, user must enter type of wood, thickness,
desired wood moisture content at the end of drying as well as whether he wants
certain drying stages or not. Then, based on this values and measured values
the device on its own chooses appropriate drying program. Automatic
control unit uses its relay outputs in order to control equipment installed in
the kiln such as heaters, flow fans, heat pumps, atomizers (sprinklers) etc.,
and achieve optimal condition in the chamber.
In semiautomatic control mode, user can set desired setpoints for
air temperature and humidity based on the personal experience, and the
automatic control unit only maintain those values inside the kiln at the
desired point.
Since MC - 904 has a built-in communication port, it can be
connected to a PC computer, which enables control of a drying process from a
distance (office or suitable operating room). Also, up to 15 kilns can be
connected to a single PC.
LCD display show parameters and current stage of drying process, while
LED displays are constantly showing air temperature, humidity and
current/average wood moisture content.
During drying process some irregular (alarm) situations can occur. They
are detected and displays show adequate warning. There are 2 types of alarm
situations which are:
- warnings - drying process continues, but error notification is shown
- alarms - drying process is interrupted because an equipment malfunction is
detected
All relevant data of a drying process are recorded in MC -
900R's internal memory. Data samples are taken every 3 hours. Internal
memory can hold such data for a period of up to 1 month.
After a power
failure has occurred, if the drying was already started, it will automatically
continue starting from the measured wood moisture content upon power supply
reconnection.
Technical data of a MC - 904 automatic control unit
are given in the following tables:
Main characteristics |
|
Power supply |
220 Vac; 50/60Hz; 300mA |
Number of inputs |
19 |
Number of outputs |
8 |
Displays |
4 - rows x 20 - characters LCD; tripled, 4 - digit x 7 -
segment LED |
Operating conditions |
T: 0 ÷ 50 °C; RH: 5 ÷ 90% |
Storage |
T: - 40 ÷ 85 °C; RH: 5 ÷ 90% |
Dimensions (WxHxD)(mm) |
250 x 115 x 135 |
Mounting hole (WxH)(mm) |
252 x 117 |
Weight |
1000g |
Inputs |
Temperature inputs
|
Number of inputs |
2 |
Range |
0 ÷ 100 °C; 10mV / °C |
Humidity inputs
|
Number of inputs |
2 |
Range |
2.7 ÷ 30 %
EMC (UGL) |
Wood moisture content inputs
|
Number of inputs |
6 |
Range |
5 ÷ 150 % |
Control inputs for temperature
|
Number of inputs |
1 |
Range |
-20 ÷ 200 °C; 10mV / °C |
Digital inputs
|
Number of inputs |
8 |
Outputs |
Relay |
Number of inputs |
8 |
Characteristics |
3-pin; 8A / 250 Vac, uninterupted load 3A max |
Number of outputs and application |
1 output for electrical heating |
1 output for water heating |
2 outputs for flow fans control |
1 output for drying |
1 output for cooling |
1 output for humidifying |
1 alarm output |
Communication |
Digital |
Communication standard |
EIA 485 |
Protocol |
S-NIGOS |
|